smearI measurements diagram small
Figure 1: Diagram of SMEAR I measurements setup (click diagram for a larger image)

 

Table. Instrumentation of the SMEAR I-station

  Parameter Device Measurement heigth
Weather dry temperature Rotronic MP100H 2, 4, 6.6, 9, 15 m
  wet temperature Rotronic MP100H 2, 4, 6.6, 9, 15 m
  wind speed Delta-TAN1 2, 4, 6.6, 9, 15 m
  wind speed Thies 2D 16 m
  wind direction Thies 2D 16 m
  PAR (photosynthetically active radiation) Li-Cor LI-190SB 16 m
  global radiation Middleton Solar SK08 16 m
  UVA Solar Light 501A UVA 16 m
  UVB Solar Light 501A SUV 16 m
  air pressure Druck DPI 260
visibility Biral VF500 visibility sensor 2 m
  precipitation Thies Laser Precipitation Monitor 2 m
  rainfall Delta-T RG1 1.5 m
  soil temperature Pt-100 0 m
Aerosols total concentration CPC TSI 3022 9 m
  size distribution DMA / CPC TSI 3025 2 m
  size distribution DMA / CPC TSI 3010 2 m
Trace gases ozone Thermo Electron corp. 49i 2, 6.6, 9, 15 m
  sulphur dioxide Thermo Electron corp. 43i-TLE 2, 6.6, 9, 15 m
  total oxides of nitrogen Thermo Electron corp. 42i-TL 2, 6.6, 9, 15 m
Scots pines photosynthesis chamber measuremets appr. 10 m
  CO2-exchange URAS 3G analysator appr. 10 m
  H2O URAS 3G analysator appr. 10 m
  PAR Li-Cor LI-190SB appr. 10 m
  temperature thermoelement Cu Ko appr. 10 m
  growth in thickness solartron sensors several heigths
  growth in length caliper appr. 10 m


smeari cabin

 

 

 

 

 

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.